Biosafety Cabinet Class-2 A2
A Biosafety Cabinet Class 2 A2 (BSC 2 A2) is a type of Class II biosafety cabinet that provides personnel, product, and environmental protection.
A BSC 2 A2 draws in room air through a front opening and passes it through a HEPA filter to provide a sterile work environment. The air is then recirculated back into the cabinet or exhausted outside the building through a HEPA filter.
BSC 2 A2 cabinets have a minimum inflow velocity of 100 feet per minute, which creates a barrier to prevent the escape of hazardous materials. They are designed for use with low to moderate-risk biological agents, such as viruses, bacteria, and cell cultures.
In addition to the HEPA filters, BSC 2 A2 cabinets also have ultraviolet lamps installed within the work area to decontaminate surfaces and equipment. They also have an alarm system that alerts the operator when the cabinet is not functioning correctly or if the filters need to be changed
application of biosafety cabinet
- Tissue culture and cell culture work
- Preparation of microbiological media and reagents
- Handling of infectious agents, such as bacteria and viruses
- DNA amplification and manipulation.
- Sterile compounding of pharmaceuticals.
- Immunological assays and serological testing
- Genetic research and manipulation of genetically modified organisms (GMOs)
- In vitro fertilization (IVF) procedures
- Handling and manipulation of potentially hazardous biological material
- Research and development of new vaccines and therapeutics
A Biosafety Cabinet Class 2 A2 (BSC 2 A2) is a type of Class II biosafety cabinet that provides personnel, product, and environmental protection.
A BSC 2 A2 draws in room air through a front opening and passes it through a HEPA filter to provide a sterile work environment. The air is then recirculated back into the cabinet or exhausted outside the building through a HEPA filter.
BSC 2 A2 cabinets have a minimum inflow velocity of 100 feet per minute, which creates a barrier to prevent the escape of hazardous materials. They are designed for use with low to moderate-risk biological agents, such as viruses, bacteria, and cell cultures.
In addition to the HEPA filters, BSC 2 A2 cabinets also have ultraviolet lamps installed within the work area to decontaminate surfaces and equipment. They also have an alarm system that alerts the operator when the cabinet is not functioning correctly or if the filters need to be changed
Ergonomic Design
- Freestanding Dual wall construction design features
- 30% Exhaust & 70% air re-circulate in the chamber
- Interior Cabinets made of stainless steel 304
- Polished AISI-304 stainless steel working surface
- Exterior CRCA Steel powder coated surface
- HEPA filter protected with laminar screen to provide incomparable uniform flow
- Sliding front safety glass sash door
- LED lighting provides uniform illumination and minimizes eye strain
- Stainless Steel arm rest to avoid pain in the hand during work
- 10° sloped front window for ergonomic work position of the operator. With predefined working, open and close position
- Each shelf can withstand up to 30 kg
- Provision for 8" Exhaust collar of the air duct to release the air in the environment
LCD CONTROL SYSTEM
- Separate Control buttons for Mains, Blower, Light & UV
- ON/OFF button with light indicator
- Button for U.V. operation with possibility of exposure time programming
- HEPA filter Life span in MM WC
- Positive pressure in the chamber
- Elapsed time counter for the U.V. light
Documentation
- User Manual In English language
- GA Wiring Diagram
- D.O.P test report
- Particle count report
- Filter test report
- IQ, OQ & PQ Documentation
TFT Control system
- Fully password protected control system
- Air speed control 0.3 to 0.8 m/s
- Button for U.V. operation with possibility of exposure time with multiple programming
- Control panel show status of: lighting, U.V
- HEPA filter clogging alarm with damage efficiency
- Elapsed time counter for the and U.V. light
- Display with real-time air speed indication
- LED light intensity measured automatically
- Fully controllable front sash with motorized facilities
alarms
- Cycle complete Audio & visual alarm
- Part failure or sensor failure alarm
- Emergency switch
- Power failure
- Door open
- Components failure
- Low battery
SAFETY
- MCB protection
- Current leakage breaker
- Over Voltage protection
Documentation
- User Manual In English language
- GA Wiring Diagram
- D.O.P test report
- Particle count report
- Filter test report
- IQ, OQ & PQ Documentation
ACCESSORIES
- Gas Connection 1/4 BSP nozzle
- Water Connection 1/4 BSP nozzle
- Stainless steel sink 100x200 mm